Resumen:
A study of the Pd-based molecular cage C1 host-guest properties against fluorescein and the drug scopolamine is reported. C1 forms an interpenetrated structure C1 2 in the presence of =40% water in H 2 O/DMSO solvent mixtures. The presence of fluorescein (FL) induces the disassembly of the C1 2 structure to form the [FL 2 ?C1] complex. Moreover, the addition of scopolamine (SCOP, a drug typically involved in drug-facilitated sexual assaults) to [FL 2 ?C1] results in fluorescein release and the formation of [SCOP?C1 2 ], obtaining a fluorescence signal proportional to the concentration of scopolamine with a limit of detection as low as 59.4 µg mL -1 . A good selectivity for scopolamine against other drugs such as MDMA, cocaine, GBL, and ketamine is observed. This is the first scopolamine detection method described to date using a molecular cage and one of the very few examples of the use of cages in indicator displacement assays. Similar concepts could be applied to the design of other molecular cage-based sensors for the detection of target analytes.
Filiaciones:
Montà-González G:
Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, Valencia, 46022, Spain
Departamento de Química, Universitat Politècnica de València, Camino de Vera s/n, Valencia, 46022, Spain
Garrido E:
Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, Valencia, 46022, Spain
Departamento de Química, Universitat Politècnica de València, Camino de Vera s/n, Valencia, 46022, Spain
CIBER de Bioingeniería Biomateriales y Nanomedicina (CIBER-BBN), Instituto de Salud Carlos III, Madrid, Spain
Climent E:
Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, Valencia, 46022, Spain
CIBER de Bioingeniería Biomateriales y Nanomedicina (CIBER-BBN), Instituto de Salud Carlos III, Madrid, Spain
Unidad Mixta de Investigación en Nanomedicina y Sensores, Universitat Politècnica de València, Instituto de Investigación Sanitaria La Fe (IIS La Fe), Avenida Fernando Abril Martorell 106, Valencia, 46026, Spain
Vicent C:
Serveis Centrals d'Instrumentació Científica, Universitat Jaume I, Avenida Sos Baynat s/n, Castelló de la Plana, 12071, Spain
:
Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, Valencia, 46022, Spain
Departamento de Química, Universitat Politècnica de València, Camino de Vera s/n, Valencia, 46022, Spain
CIBER de Bioingeniería Biomateriales y Nanomedicina (CIBER-BBN), Instituto de Salud Carlos III, Madrid, Spain
Unidad Mixta de Investigación en Nanomedicina y Sensores, Universitat Politècnica de València, Instituto de Investigación Sanitaria La Fe (IIS La Fe), Avenida Fernando Abril Martorell 106, Valencia, 46026, Spain
Unidad Mixta UPV-CIPF de Investigación en Mecanismos de Enfermedades y Nanomedicina, Universitat Politècnica de València, Centro de Investigación Príncipe Felipe, Avenida Eduardo Primo Yúfera 3, Valencia, 46012, Spain
Martí-Centelles V:
Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, Valencia, 46022, Spain
Departamento de Química, Universitat Politècnica de València, Camino de Vera s/n, Valencia, 46022, Spain
CIBER de Bioingeniería Biomateriales y Nanomedicina (CIBER-BBN), Instituto de Salud Carlos III, Madrid, Spain
hybrid
|